Full Body System: Remove the Cover
Tools required
- 3/8"-drive Ratchet
- T27 Torx Bit
Procedure
IMPORTANT: Always Disconnect Power from the System when Servicing.
- Remove the black bezel around the computer. There are two screws on each side of the bezel.
- Remove two screws from center of the cover. One screw is at the top center and one screw is at the bottom center.
- To remove the full length aluminum door handle, remove the torx head screws with ratchet and T27 torx bit.
- Remove the torx head screws under the full length aluminum door handle. The cover will open on one side of the unit (the other side will be attached at the hinge).
- In units manufactured prior to January, 1993, the ballasts and relay box will be accessible.
CAUTION: Do Not Touch the Round Capacitors on each Ballast as They will Hold a Charge Even with No Power to the Unit!
If you need assistance, please contact us.